亚洲麻豆äV无码成人片在线观看_国产三級精品专区_最近免费中文字幕中文高清_精品无人区无码乱码毛片国产,国产欧美日韩综合精品一区二区三区,日日噜噜夜夜狠狠久久丁香五月,婷婷国产天堂久久综合五月,99精品欧美一区蜜桃在线,日韩精品一区二区三区视频播放,国产亚洲日韩a欧美在线观看,国产精品亚洲一区二区免费国产,久久久久久久99精品免费观看 ,亚洲精品成人片在线观看精品字幕,av喷水高潮喷水在线观看com,亚洲欧美日韩久久精品第一区,精品免费一区二区在线 ,国产日韩精品中文字无码_久久久久人妻精品一区蜜桃_久久久97精品国产一区蜜桃_国产做国产爱免费视频

Products

LungsReady Breathing Simulator

Model TYE6060
Product size(mm) 1530×755×540

Click here to watch video


Outline

The LungsReady Breathing Simulator creates an algorithm model based on the human body physiological and pathological characteristics of respiratory mechanics, and can simulate normal and different disease state of the human respiratory system by adjusting the mechanical parameters. It canbe used with real ventilators and anesthesia machines to trigger and respond as a real patient does, make it an ideal choice for ventilation management training in anesthesia, critical care, emergency medicine, respiratory care etc. It also finds wide applicationin respiratory disease research and real ventilator detection and calibration.


Intended Use

· Basic to advanced mechanical ventilation

· Simulate virtually any patient with respiratory conditions

· Respiratory disease research

· Development and testing for ventilators and other respiratory therapy devices


Features

·LungsReady workstation supports height adjustment from 0 to 40cm.

· 3L air storage capacity. By changing parameters, LungsReady is capable of simulating respiratory disease from the full range of patients – neonatal to adult, male to female with different weights.

·LungsReadyautomatically detects parameter adjustments and responds and reacts accordingly.

·LungsReadyuses high-precision bearings and ball screws to perform linear motion. Besides, a high-sensitivity encoder is applied for detection, which can precisely control the linear movement distance, thus accurately controlling the breathing air volume and achieving high-speed, smooth and noise-free operation.

·LungsReadycan detect the flow rate, pressure, tidal volume of the ventilator and anesthesia machine and generate corresponding waveforms (F-T, Paw-T, Pmus-T, Palv-T, V-T) and ring diagrams (F-V, Paw-V, Paw-F).

·When LungsReady simulates a patient without spontaneous breathing, controlled ventilation can be done by a ventilator. LungsReady can perform the corresponding breathing movement according to the mode and parameter settings of the mechanical ventilation.

·When LungsReady simulates a patient who has spontaneous breathing, the spontaneous breathing can trigger the mechanical ventilation. If the spontaneous breathing is strong, patient "fighting the ventilator" waveform will be generated. 

·The system comes with 15 real clinical cases and 50 basic respiratory mechanics models of healthy people and COPD, ARDS as well as other types of patients.Basic respiratory mechanics models can be expanded infinitely according to the needs of teachers.

·More than 20 common parameters such as compliance, airway resistance, respiratory muscle pressure, respiratory time ratio, respiratory frequency, functional residual capacity can be adjusted to affect the change of system breathing work. In addition to linear compliance, nonlinear compliance can also be adjusted.

·The changing trend of the patient's condition can be simulated through the trend breathing settings, such as simulating the gradual weakening of the respiratory muscle work after gas anesthesia; simulating the fluctuation of patient's breathing movement through random breathing to add more realism; simulating unstable breathing with diseases such as asthma.

·Quick buttons for common human symptoms and diseases such as coughing, sighing and suffocation can simulate the impact of coughing on ventilation, sigh-like breathing and waveform changes when suffocation occurs.

·LungsReady can monitor the real-time changes of 18 parameters such as respiratory rate, I:E ratio, and peak airway pressure with respiratory movement, and quickly set up the displayed monitoring parameters.

·LungsReady comes with built-in dynamic respiratory mechanics models, which can dynamically change with the performance of inhalation and exhalation. The range of tidal volumes can be set according to weight. There is corresponding indication for normal, insufficient, or excessive tidal volumes.

·The system supports operation review. Users can view operation log details, important parameter trends, and monitoring waveforms.Accounts can be created in the system and each user can see their own operation review, be it teaching or training.

·Running process can be stopped at any time and the waveforms can be frozen for comparative analysis.

·Instructors can adjust monitoring parameters, including heart rate and other values as well as dozens of common ECG waveforms.

·Learners can check the simulation monitoring interface and view the ECG waveforms of different leads on the learner's tablet display.

·Thesystem can generate a 12-lead ECG checklist for students to view.

·Instructors can edit no less than 50 kinds of laboratory tests such as blood gas analysis, chest X-ray, chest CT, lung functions, etc., and send them to learners for them to view through the learner's tablet display.

Tellyes, Virtually Real

Stock code :833047

Address:2nd & 3rd Floor, West 6th Building, 18 West HaiTai Road, Tianjin, China

Postcode:300384

Phone:4006-355-510

+86-22-83711066

Fax:+86-22-83711065

Email:info@tellyes.com

Tellyes Scientific INC.  Copyright  津ICP備14006255號(hào)-1
措美县| 武穴市| 红安县| 麦盖提县| 高州市| 望城县| 安阳市| 信丰县| 资源县| 江达县| 长丰县| 盐城市| 丰宁| 旬阳县| 南皮县| 望谟县| 休宁县| 宁国市| 连江县| 永寿县| 安乡县| 紫云| 新野县| 柏乡县| 黄山市| 治县。| 西城区| 育儿| 平阴县| 拉萨市| 陆川县| 杂多县| 荣成市| 尉犁县| 宜黄县| 扶沟县| 海南省| 惠东县| 永昌县| 武平县| 文成县|